{"product_id":"carbon-monoxide-gas-and-smoke-sensor-moes-s03-cgs-eu-ms","title":"Carbon monoxide, gas and smoke sensor MOES S03-CGS-EU-MS","description":"\u003ch3\u003eMOES S03-CGS-EU-MS Carbon Monoxide and Smoke Detector\u003c\/h3\u003e\n\u003cp\u003eKeep your home safe with the multifunctional MOES S03-CGS-EU-MS detector, which continuously monitors carbon monoxide (CO) levels, flammable gases, and the presence of smoke. The device uses an electrochemical CO sensor and a photoelectric smoke sensor, and if a hazard is detected, it triggers an audible alarm with a volume of at least 85 dB and a visual indicator. The easy-to-read display shows current measurements, including air temperature and humidity, and a three-color indicator makes it easy to assess the situation. Additional features include a built-in 1000 mAh battery, adjustable screen brightness, and the ability to customize gas detection sensitivity.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"A black-and-white MOES device with a digital display and a green circle against a smoky background\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25456\/33686\/3-80fcef1d-4d3c-464a-8dfe-dcf60e94fb9e.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eDetect Hazards in Time\u003c\/h3\u003e\n\u003cp\u003eThe MOES S03-CGS-EU-MS measures carbon monoxide concentrations in the range of 0 to 999 ppm, and the default CO alarm threshold is 49 ppm. The device also detects flammable gases, such as methane and butane, as well as smoke, using a photoelectric sensor. This makes it ideal for use in rooms with gas stoves, water heaters, or fireplaces, among other settings, ensuring continuous monitoring of various types of hazards.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"A gas stove with flames, a car exhaust pipe emitting smoke, a white space heater in a bathroom, and a fireplace with a fire\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25456\/33686\/1-57b48b99-c0d2-4b7d-8868-2df6545006ff.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eClear Hazard Level Indication\u003c\/h3\u003e\n\u003cp\u003eThe sensor uses a three-level light indicator in green, yellow, and red, allowing you to easily identify the current hazard level. For carbon monoxide, green corresponds to a concentration of 0–49 ppm, yellow to 50–99 ppm, and red to values exceeding 99 ppm. For flammable gases, these levels are, respectively, below 5% LEL, from 5% to below 15% LEL, and at least 15% LEL. In the case of smoke, however, the indicator displays values below 0.15 dB\/m, from 0.15 to below 0.30 dB\/m, and 0.30 dB\/m or higher. This allows the device to quickly assess the indicated hazard level.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"A MOES device in a wall outlet with a display and a red circle against the background of a gas stove\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25456\/33686\/5-15988071-b8c5-4137-94d0-6acff9376cc1.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eAudible and visual alarms—don’t miss a warning\u003c\/h3\u003e\n\u003cp\u003eWhen the sensor detects a dangerous level of monitored substances or smoke, it will alert you with an audible alarm of at least 85 dB and a visual alarm. This allows you to quickly notice the warning and take appropriate action. The device also features a mute function that can be activated using a button on the front panel. The indicator’s flashing frequency depends on the type and level of the detected hazard—for gases, it is 1 s, 0.5 s, or 0.25 s, and for smoke, 0.5 s.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"Two black-and-white devices with displays and green circles above a transparent base\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25456\/33686\/2-7b3aa1ab-7323-465e-a7a2-8a0efaf0117e.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eMonitor Temperature and Humidity\u003c\/h3\u003e\n\u003cp\u003eIn addition to detecting hazards, the MOES S03-CGS-EU-MS also provides information about indoor conditions. On the color display, you can check the current temperature and relative humidity. The humidity measurement range is from 0% to 95% RH, with a tolerance of ±5%, under non-condensing conditions. All the most important information is displayed on a single screen, making it easy to monitor both safety and environmental conditions.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"A MOES device with a display in a wall outlet and on the kitchen countertop\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25456\/33686\/9-613ca53c-5fa2-4b08-807d-8298bae68618.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eConvenient operation and settings adjustment\u003c\/h3\u003e\n\u003cp\u003eThe well-designed control panel provides quick access to the device’s most important functions. The central button turns the sensor on and performs a self-test, while separate controls are used to adjust the display brightness and mute the alarm. You can also adjust the sensitivity for detecting flammable gases—level S1 indicates lower sensitivity for methane, while S2 provides higher sensitivity for butane, alcohol, and other flammable gases.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"A black-and-white MOES device with a display in a wall outlet in the kitchen next to a vase of flowers\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25456\/33686\/10-c8bfc3e4-8af9-4d6f-9a01-4097b8254438.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eOperates Even During a Power Outage\u003c\/h3\u003e\n\u003cp\u003eThe MOES S03-CGS-EU-MS is powered by a 100–240 V, 50\/60 Hz electrical outlet. It also features a built-in 1000 mAh rechargeable battery that provides temporary emergency power in the event of a power outage. This allows the device to continue operating even if the mains power is unexpectedly cut off.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"A black-and-white MOES device with a display on a wooden table in front of a fireplace with a fire\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25456\/33686\/7-fe7de1c2-8276-43c4-b8ae-07b1db4875c2.jpg\"\u003e\n\u003c\/p\u003e\u003ch3\u003eEasy Installation and Sturdy Construction\u003c\/h3\u003e\n\u003cp\u003eThe sensor features a compact housing measuring 125.5 × 60.5 × 36.3 mm, so it doesn’t take up much space. The replaceable plug allows for easy replacement of the power connector without tools, enhancing user convenience. The housing is made of flame-retardant ABS plastic, and the operating temperature range is from -10°C to 50°C.\u003c\/p\u003e\n\u003cp\u003e\n\u003cimg alt=\"A MOES device with a display and a red circle plugged into a white wall outlet\" border=\"0\" src=\"https:\/\/assets.innpro.pl\/25456\/33686\/8-75bdd757-84b7-4ac3-ad8b-ad9288520793.jpg\"\u003e\n\u003c\/p\u003e\n\u003ch3\u003eIncluded in the package\u003c\/h3\u003e\n\u003cul class=\"list-disc pl-5\"\u003e\n\u003cli\u003eMOES sensor x1\u003c\/li\u003e\n\u003cli\u003eUser manual x1\u003c\/li\u003e\n\u003cli\u003ePlug x1\u003c\/li\u003e\n\u003cli\u003ePackaging safety insert x1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer\u003c\/th\u003e\n\u003ctd\u003eMOES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003ctd\u003eS03-CGS-EU-MS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCarbon monoxide detection technology\u003c\/th\u003e\n\u003ctd\u003eElectrochemical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmoke sensor type\u003c\/th\u003e\n\u003ctd\u003ePhotoelectric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO measurement range\u003c\/th\u003e\n\u003ctd\u003e0–999 ppm (±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDefault CO alarm threshold\u003c\/th\u003e\n\u003ctd\u003e49 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCO concentration levels\u003c\/th\u003e\n\u003ctd\u003eGreen: 0–49 ppm; yellow: 50–99 ppm; red: above 99 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlammable gas detection levels\u003c\/th\u003e\n\u003ctd\u003eGAS Lv1–Lv3 (Lv3: ≥15% LEL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlammable gas alarm threshold\u003c\/th\u003e\n\u003ctd\u003eGAS Lv2 (≥5% LEL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFlammable gas concentration levels\u003c\/th\u003e\n\u003ctd\u003eGreen: below 5% LEL; yellow: 5% to below 15% LEL; red: ≥15% LEL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmoke alarm threshold\u003c\/th\u003e\n\u003ctd\u003e≥0.15 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmoke levels\u003c\/th\u003e\n\u003ctd\u003eGreen: below 0.15 dB\/m; yellow: 0.15 to below 0.30 dB\/m; red: ≥0.30 dB\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas detection sensitivity adjustment\u003c\/th\u003e\n\u003ctd\u003eS1 (low sensitivity for methane), S2 (high sensitivity for butane, alcohol, and other flammable gases)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHumidity measurement range\u003c\/th\u003e\n\u003ctd\u003e0–95% RH (±5%, non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature measurement\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm signaling\u003c\/th\u003e\n\u003ctd\u003eAudible and visual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm volume\u003c\/th\u003e\n\u003ctd\u003e≥85 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHazard level indication\u003c\/th\u003e\n\u003ctd\u003eThree-level (green, yellow, red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eGas indicator flashing frequency\u003c\/th\u003e\n\u003ctd\u003eGreen: 1 s; yellow: 0.5 s; red: 0.25 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSmoke indicator flashing frequency\u003c\/th\u003e\n\u003ctd\u003e0.5 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAlarm Mute Function\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSelf-Test Function\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay Brightness Adjustment\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMains Power Supply\u003c\/th\u003e\n\u003ctd\u003e100–240 V, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBackup Battery\u003c\/th\u003e\n\u003ctd\u003eBuilt-in, 1000 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eReplaceable plug\u003c\/th\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHousing material\u003c\/th\u003e\n\u003ctd\u003eFlame-retardant ABS plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating temperature\u003c\/th\u003e\n\u003ctd\u003e–10°C to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e125.5 × 60.5 × 36.3 mm (without plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Moes","offers":[{"title":"Default Title","offer_id":63316737917315,"sku":"S03-CGS-EU-MS","price":31.5,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/4286\/1443\/files\/66103_1_1.webp?v=1794960646","url":"https:\/\/grozs.lv\/ru\/products\/carbon-monoxide-gas-and-smoke-sensor-moes-s03-cgs-eu-ms","provider":"Grozs.lv","version":"1.0","type":"link"}